VALSPAR CORP -- PAINT PRODUCT, 0V81016184A011 -- 8010-00N037103
=====================  Product Identification  =====================

Product ID:PAINT PRODUCT, 0V81016184A011
MSDS Date:04/11/1986
FSC:8010
NIIN:00N037103
MSDS Number: BQRPY
=== Responsible Party ===
Company Name:VALSPAR CORP
Address:1101 THIRD ST S
City:MINNEAPOLIS
State:MN
ZIP:55415
Country:US
Info Phone Num:612-332-7371
Emergency Phone Num:612-332-7371
CAGE:13374
=== Contractor Identification ===
Company Name:VALSPAR CORP
Address:1101 THIRD ST S
City:MINNEAPOLIS
State:MN
ZIP:55414
Country:US
Phone:800-228-5635
CAGE:13374
Company Name:VALSPAR CORPORATION
Address:1101 THIRD ST. SOUTH
Box:City:MINNEAPOLIS
State:MN
ZIP:55415
Country:US
Phone:612-332-7371/888-345-5732
CAGE:23526

=============  Composition/Information on Ingredients  =============

Ingred Name:XYLENE
CAS:1330-20-7
RTECS #:ZE2100000
OSHA PEL:100 PPM,150 STEL
ACGIH TLV:100 PPM,150 STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (TALC)
CAS:14807-96-6
RTECS #:WW2710000
OSHA PEL:2 MG/M3 RDUST
ACGIH TLV:2 MG/M3 RDUST

Ingred Name:EPOXY RESIN; (PHENOL, 4,4'-(1-METHYLETHYLIDENE) BIS-POLYMER
    WITH (CHLOROMETHYL) OXIRANE)

Ingred Name:BUTYL ALCOHOL; (N-BUTYL ALCOHOL)
CAS:71-36-3
RTECS #:EO1400000
OSHA PEL:100 PPM
ACGIH TLV:S, C 50 PPM; 9293
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:2-PENTANONE, 4-METHYL-; (METHYL ISOBUTYL KETONE)  (SARA
    III)
CAS:108-10-1
RTECS #:SA9275000
OSHA PEL:100 PPM/75 STEL
ACGIH TLV:50 PPM/75 STEL; 9293
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:RESP IRRITATION, DIZZINESS, NAUSEA,
    LOSS OF CONSCIOUSNESS. POSSIBLE SENSITIZATION. NOTICE: REPORTS HAVE
    ASSOCIATED REPEATED AND PROLONGED OCCUPATIONAL OVEREXPOSURE TO
    SOLVENTS WITH PERMANENT BRAIN AND  NERVOUS SYSTEM DAMAGE.
    INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING AND INHALING
    CONTENTS MAY BE HARMFUL OR FATAL.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHALATION: REMOVE PERSON FROM EXPOSURE AREA. IF BREATHING
    HAS STOPPED, USE MOUTH-TO-MOUTH RESUSCITATION AND GET MEDICAL
    ATTENTION. EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SKIN:
    WASH WITH SOAP  AND WATER. INGESTION: GET MD ATTENTION IMMEDIATELY
    .

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:79F,26.1C
Lower Limits:1%
Upper Limits:11.2%
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS
    .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT . CONTAINERS EXPOSED TO FIRE SHOULD BE KEPT
    COOL WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:NONE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILATE AREA. AVOID BRTHG OF VAPORS. USE
    NIOSH/MSHA APPROVED SELF-CONTAINED BREATHING APPARATUS OR AIRMASK
    FOR LARGE SPILLS IN CONFINED AREA. ELIMINATE IGNITION SOURCES.
    REMOVE WITH INERT ABSORBENT  AND NON-SPARKING TOOLS. AVOID ALL
    PERSONAL CONT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS AND OPEN
    FLAMES. KEEP CONTAINER CLOSED WHEN NOT IN USE. DO NOT STORE ABOVE
    120F.
Other Precautions:CNTNRS SHOULD BE GROUNDED WHEN POURING. AVOID FREE
    FALL OF LIQ IN EXCESS OF FEW INCHES. BASED ON PROD FL PT & VAP
    PRESS SUITABLE STOR SHOULD BE PROVIDED I/A/W OSHA REG 1910-106.
    EMPTY CNTNRS MAY CONTA IN PROD RESIDUE INCL FLAM/EXPLO (SUPDAT)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:WEAR APPROPRIATE, PROPERLY FITTED NIOSH/MSHA
    APPROVED RESPIRATOR DURING AND AFTER APPLICATION UNLESS AIR
    MONITORING VAPOR/MIST LEVELS ARE BELOW APPLICABLE LIMITS. FOLLOW
    RESPIRATOR MANUFACTURERS DIREC TIONS FOR RESPIRATOR USE.
Ventilation:REQUIRED FOR SPRAYING OR IN CONFINED AREA, VENTILATION
    EQUIPMENT SHOULD BE EXPLOSION PROOF. ELIMINATE IGNITION SOURCES.
Protective Gloves:NEOPRENE OR OTHER NONPOROUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NEOPRENE OR PLASTIC APRON AND PROTECTIVE
    CLOTHING COVERING EXPOSED SKIN AREAS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
OTHER PRECAUTIONS: VAPORS. DO NOT CUT, PUNCTURE OR WELD ON OR NEAR
    CONTAINER. ALL LABEL WARNINGS MUST BE OBSERVED UNTIL CONTAINER HAS
    BEEN CLEANED OR RECONDITIONED.

==================  Physical/Chemical Properties  ==================

HCC:F4
Boiling Pt:B.P. Text:237F,114C
Vapor Pres:15 @ 68F
Vapor Density:3.66
Spec Gravity:1.42
Evaporation Rate & Reference:1.6 (BUTYL ACETATE=1)
Solubility in Water:NO
Appearance and Odor:LIQUID, ODOR NORMAL FOR COATINGS PRODUCT.
Percent Volatiles by Volume:30.89

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NOT APPLICABLE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:SILICON DIOXIDE, CARBON
    DIOXIDE/MONOXIDE, METAL OXIDES.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE IN CHEMICAL DISPOSAL AREA OR IN A MANNER
    THAT COMPLIES WITH LOCAL, STATE, AND FEDERAL REGULATIONS. DO NOT
    INCINERATE CLOSED CONTAINERS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.