Spartan Chemical Company, Inc.
Material Safety Data Sheet
Hide details for SECTION I:  PRODUCT INFORMATIONSECTION I: PRODUCT INFORMATION

Product Name or Number (as it appears on label):Product Division:
NABC NON-ACID DISINFECTANT BATHROOM CLEANER
Product Number: 7116; 7496
Janitorial
Spartan Chemical Company, Inc.
Product/Technical Information:
1-(800)-537-8990
1110 Spartan Drive
Medical Emergency:
1-(888)-314-6171 (24 hours)
Maumee OH 43537
Chemical Leak/Spill Emergency:
CHEMTREC 1-(800) 424-9300 (24 hours)
Shipping Description:
Disinfectants, liquid, n.o.s.
NFPA Ratings:
HMIS Ratings:
Health:
1- Slight
Health:
1- Slight
Fire:
0 - Minimal
Fire:
0 - Minimal
Reactivity:
0 - Minimal
Reactivity:
0 - Minimal
Pers. Prot. Equip.:
See Section VIII


Hide details for SECTION II:  HAZARDOUS INGREDIENTSSECTION II: HAZARDOUS INGREDIENTS
(Listed when present at 1% or greater, carcinogens at 0.1% or greater) All component chemicals are listed or exempted from listing on the "TSCA Inventory" of chemical substances maintained by the U.S. Environmental Protection Agency.
Chemical Name(s)
% W
CAS Registry No.
Table Z- 1 - A
NTP, IARC or OSHA Carcinogen
TWA mg/m3
STEL mg/m 3
CELING mg/m3
Isopropyl alcohol
1-5
67-63-0
980
1225
Not Established
No
Alcohol ethoxylate
1-5
68439-46-3
Not Established
Not Established
Not Established
No
Dialkyl dimethyl ammonium chloride
< 1.0
68424-95-3
Not Established
Not Established
Not Established
No
Alkyl dimethyl benzyl ammonium chloride
< 1.0
68424-85-1
Not Established
Not Established
Not Established
No


Hide details for SECTION III:  PHYSICAL DATASECTION III: PHYSICAL DATA
Boiling Point:
210 °F
Vapor Pressure:
Unknown
Vapor Density (AIR = 1):
Unknown
Solubility in Water:
Complete
pH:
6.0-7.0
Specific Gravity (H2O=1):
0.995 @ 75 F
Evaporation Rate (but.ace.=1):
<1
Percent Solid by Weight:
2
Physical State:
Liquid
Appearance & Odor:
Blue colored liquid, floral fragrance



Hide details for SECTION IV:  FIRE & EXPLOSIVE HAZARD DATASECTION IV: FIRE & EXPLOSIVE HAZARD DATA

Flash Point:
> 210°F
Method Used:
ASTM-D56
Flammable Limits:
NA
Flame Extension:
N/A
Extinguishing Media:
Product does not support combustion. Use extinguishing media appropriate for surrounding fire.
Special Fire Fighting Procedures:
Wear NIOSH approved self-contained breathing apparatus and protective clothing. Cool fire-exposed containers with water spray.
Unusual Fire & Explosive Hazards:
Products of combustion are toxic.
Hide details for SECTION V:  HEALTH HAZARD DATASECTION V: HEALTH HAZARD DATA
Threshold Limit Value:
    Not Established
Primary Routes of Entry:
Inhalation, Skin Contact, Eyes and Ingestion
Effects of Overexposure-
Conditions to Avoid:
Causes moderate eye irritation. Harmful if absorbed through the skin. May be harmful if swallowed. Inhalation of product mist may cause respiratory irritation.
Avoid contact with eyes, skin or clothing. Do not swallow. Avoid breathing product mist. Wash thoroughly with soap and water after handling.
Conditions Aggravated by Use:
Use of this product may aggravate preexisting skin; eye and respiratory disorders including asthma and dermatitis.
Emergency & First Aid Procedures:
Eyes:
Hold eye open and rinse slowly and gently with water for 15-20 minutes. Remove contact lenses; If present after the first 5 minutes; then continue rinsing eye. Call a poison control center or doctor for treatment advice.
Skin:
Take off contaminated clothing. Rinse skin immediately with plenty of water for 15-20 minutes. Call a poison control center or doctor for treatment advice.
Ingestion:
Do not induce vomiting. Drink one or two glasses of water to dilute product. Call a poison control center or doctor for treatment advice. Do not give anything by mouth to an unconscious person.
Inhalation:
In case of respiratory irritation; move person to fresh air. Get medical attention if irritation persists.


Hide details for SECTION VI:  REACTIVITY DATASECTION VI: REACTIVITY DATA

Stability:
Stable
Incompatible Materials:
Strong oxidizers
Hazardous Decomposition Products:
None
Hazardous Polymerization:
Will Not Occur


Hide details for SECTION VII:  SPILL OR LEAK PROCEDURESSECTION VII: SPILL OR LEAK PROCEDURES
Steps to be Taken in Case
Material is Released or Spilled:
Small spills of one gallon or less may be flushed with plenty of water to sanitary sewer system (If permitted by local sewer regulations). Dike and contain large spills with inert material and transfer liquid to containers for disposal. Keep spill out of storm sewers and waterways.
Waste Disposal Method:
Dispose of in compliance with all federal, state and local laws and regulations.


Hide details for SECTION VIII:  SPECIAL PROTECTION INFORMATIONSECTION VIII: SPECIAL PROTECTION INFORMATION

Respiratory Protection:
Not normally required when good general ventilation is provided. However, if exposure limits (see Section II) are exceeded or if respiratory irritation occurs, use of a NIOSH approved respirator suitable for the use-conditions and chemicals in Section II should be considered.
Ventilation:
Provide good general ventilation. Local exhaust ventilation may be necessary for some operations.
Protective Gloves(Specify Type):
Rubber or other Impervious gloves are recommended for frequent or prolonged contact.
Eye Protection(Specify Type):
Splash goggles or safety glasses are recommended.
Other Protective Equipment:
See 29 CFR 1910.132-138



Hide details for SECTION IX:  SPECIAL PRECAUTIONSSECTION IX: SPECIAL PRECAUTIONS

Precautions; Handling & Storing:
Keep out of reach of children
Other Precautions:
NA

© SCC 03/25/2008Name:Ronald T. CookTitle:Manager, Regulatory Affairs
NABC NON-ACID DISINFECTANT BATHROOM CLEANEREffective Date:03/25/2008Supercedes:12/14/2005
Ref: 29 CFR 1910.1200 (OSHA)Changes:Formula Revision
This document has been prepared using data from sources considered technically reliable. It does not constitute a warranty, express or implied, as to the accuracy of the information contained herein. Actual conditions of use and handling are beyond sellers control. User is responsible to evaluate all available information when using product for any particular use and to comply with all Federal, State and Local laws and regulations.